Features
- Choice of 3 ratios.
- Max. air drive pressure Pa=150 psig(10.3 bar).
- Choice of seal materials.
- Higher outlet pressure to 20000 psig(1379 bar.
- No lubricator required.
Booster Model Code | Max. Rated Gas Supply | Min. Rated Gas Supply | Max. Rated Gas Outlet (Psig) | Actual ML Per Cycle | Outlet Stall Press. Formula | Compression Ratio. Max | Inlet & Outlet Gas Port | ||
---|---|---|---|---|---|---|---|---|---|
Insert Gas | Hydrogen | Oxygen | |||||||
CGB06-2S-7 | 9000 Psig | 200 Psig | 9000 | 9000 | 5000 | 51ML | 60 Pa | 25:1 | ¼” HF |
CGB06-2S-100 | 12000 Psig | 100 Psig | 12000 | 12000 | 5000 | 32ML | 100 Pa | 25:1 | ¼” HF |
CGB06-2S-150 | 20000 Psig | 250 Psig | 20000 | 15000 | 5000 | 20ML | 150 Pa | 25:1 | ¼” HF |
CGB06-2S-50 | 7500 Psig | 100 Psig | 7500 | 7500 | 7500 | 32ML | 50 Pa | 25:1 | ¼” HF |
CGB06-2S-75 | 11250 Psig | 250 Psig | 11250 | 11250 | 5000 | 20ML | 75 Pa | 25:1 | ¼” HF |
1. All model code listed are standard.
Oxygen gas service add “-O” after the model codes.
Hydrogen gas service add “-H” after the model codes.
Replaces all Buna static and dynamic seals in the drive section of the gas booster
add“-V” after the model codes.
With external pilot port on air drive section add“-X” after the model codes.
With external pilot port on air drive section& pressure switch add “-XS” after the model codes.
2. Other sizes, materials and types are available upon request. For special
requirements, please contact us