AIR LINE FILTER
Air line Filters
MARUTI PNEUMATICS PREMIUM FILTER SERIES
Working Principle
Coalescing is a continuous natural process in which oil, water and solid particles that pass through the filter element come into contact with a fiber strand and unite with other collected aerosol to form droplets. The droplets fall to the bottom of the housing and are drained away.
MARUTI PNEUMATICS PREMIUM FILTER SERIES
Model |
Element Grade |
Pipe Size BSP |
Flow Rate Cfm @ 7 Bar |
Max Working Pressure |
T-060 |
P,Y,A |
½” |
60 |
16 |
T-100 |
¾” |
100 |
16 |
|
T-150 |
1” |
150 |
16 |
|
T-265 |
1 ½” |
265 |
16 |
|
T-400 |
2” |
400 |
16 |
|
T-500 |
2” |
500 |
16 |
|
T-600 |
2” |
600 |
16 |
|
T-800 |
2” |
800 |
16 |
|
T-900 |
3” |
900 |
16 |
|
T-1450 |
3” |
1450 |
16 |
|
T-1630 |
4” |
1630 |
16 |
Description |
Element Grade |
||
P |
Y |
A |
|
Filter Element |
Borosilicate |
Borosilicate |
Activated Carbon |
Housing |
Extruded Aluminum Alloy |
||
Particle Removal |
5 Micron |
0.01 Micron |
0.01 Micron |
Max. Oil Carry Over (mg/m3) |
5 |
0.01 |
0.003 & Remove Odour |
Max. Working Pressure |
16 Bar |
16 Bar |
16 Bar |
Max. Working Temperature |
80’ C |
80’ C |
80’ C |
Initial Pr. Loss |
0.03 Bar |
0.1 Bar |
0.06 Bar |
Pr. drop for element change |
0.4 Bar |
0.4 Bar |
0.4 Bar |
*Precede type A with type P & Y
Correction Factor
Pressure (Bar) | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 20 |
---|---|---|---|---|---|---|---|---|---|
Correction Factor | 0.65 | 0.85 | 1.00 | 1.13 | 1.25 | 1.36 | 1.46 | 1.56 | 1.7 |